您好,是时候升级你的浏览器了!你正在使用 Internet Explorer 的过期版本,Internet Explorer 8 可以为你提供更快、更安全的浏览体验,提供更好的隐私保护。立即下载

Details

Home > Repairs > System accessories > Details

System accessories


Lamps for DLP system


Average service life of lamps is 6000 hours.

While using, the lamps attenuation degree become different, lead to brightness difference between DLP screen.

Do brightness consistency adjustment every 1000 hours using.

Attenuation results in the decrease of brightness, broken lamp would result in a black display.

Provide all series of lamps, be applied to Barco, Vtron, Mitsubishi, Christie, GQY, Toshiba, Delta, YOUNG Optics, LUMENS and other brands.


Color wheels for DLP system


Color wheel is rotating at high speed when in work condition. After long working hours, the color shade will decay, lead to dark colored display pictures. Replace it after 2000 hours using.

Dust stick on the color wheel can also lead to dark colored display pictures. Regular cleaning can be improve display results.

If color wheel failure occurs, it will cause a black display.

Provide all series of color wheels, be applied to Barco, Vtron, Mitsubishi, Christie, GQY, Toshiba, Delta, YOUNG Optics, LUMENS and other brands.


DMD chips


DMD chip is the core component of DLP system. Its fault usually caused by non-professional maintenance when disassembling. Suggested that non-professional workers do not open the optical engine.

If DMD chip failure occurs, it will cause a black display.

It can only be replaced when failure happened.

Provide all series of DMD chips, be applied to Barco, Vtron, Mitsubishi, Christie, GQY, Toshiba, Delta, YOUNG Optics, LUMENS and other brands.


DLP Optical lenses


Optical lenses usually be damaged when disassembly in maintenance process by non-professional workers. Suggested that non-professional workers do not open the optical engine.

Dust sticky on optical lenses would reduce the brightness and color of display. Clean them regularly.

Provide all series of DMD chips, be applied to Barco, Vtron, Mitsubishi, Christie, GQY, Toshiba, Delta, YOUNG Optics, LUMENS and other brands.



DLP Lighting Starter Board


DLP lighting starter board is used to launch the lamp. Its fault will result in black screen display.

Failure of lighting starter board is mainly caused by the voltage instability or frequent switch.

The solution is replacement when the lighting starter board fault happened.

Provide all series of lighting starter board, be applied to Barco, Vtron, Mitsubishi, Christie, GQY, Toshiba, Delta, YOUNG Optics, LUMENS and other brands.




DLP POWER


DLP power failure will lead to an optical engine cannot be started and result in black screen display.

It is easily caused failure that operation under high temperature or instable voltage.

DLP power failure could be repaired or replaced according to specific situation.

Provide all series of DLP power, be applied to Barco, Vtron, Mitsubishi, Christie, GQY, Toshiba, Delta, YOUNG Optics, LUMENS and other brands.





Fan for DLP power


Fan is mainly used for heat dissipation.

Fan fault causes an optical engine cannot be started.

Recommend replace it when fan fault.

Provide all series of fan, be applied to Barco, Vtron,  Mitsubishi, Christie, GQY, Toshiba, Delta, YOUNG Optics, LUMENS and other brands.




DLP six axis adjustment


DLP six axis adjustment is rarely out of order. Need to be used in upgrade case.

Provide all series of DMD chips, be applied to Barco, Vtron,  Mitsubishi, Christie, GQY, Toshiba, Delta, YOUNG Optics, LUMENS and other brands.




DLP optical engine(single lamp)


The key part of DLP system.

Optical engine is keep on upgrading. Upgrading DLP system with new optical engine is economic and efficient.

Provide all series of optical engines, be applied to Barco, Vtron,  Mitsubishi, Christie, GQY, Toshiba, Delta, YOUNG Optics, LUMENS and other brands.



DLP optical engine(double lamps)


The key part of DLP system.

Optical engine is keep on upgrading. Upgrading DLP system with new optical engine is economic and efficient.

Provide all series of optical engines, be applied to Barco, Vtron,  Mitsubishi, Christie, GQY, Toshiba, Delta, YOUNG Optics, LUMENS and other brands.




DLP optical engine(DELTA)


The key part of DLP system.

Optical engine is keep on upgrading. Upgrading DLP system with new optical engine is economic and efficient.



DLP power (with shell)


DLP power failure will lead to optical engines cannot be started and black screen display.

It is easily caused failure that operation under high temperature or instable voltage.

DLP power failure could be repaired or replaced according to specific situation.

Provide all series of DLP power, be applied to Barco, Vtron,  Mitsubishi, Christie, GQY, Toshiba, Delta, YOUNG Optics, LUMENS and other brands.



DLP remote control


DLP remote control is mainly used for DLP debugging, much more convenient than software. Remote control the display in different locations when debugging.

Recommend buy new one when lost or broken.

It is suitable for the remote control of optical engines. Apply to DELTA, Lumens  and other brands.



DLP light reflector


DLP optical reflector mainly be used in optical path reflection.

DLP optical reflector fault is rare, only be broken by careless in maintenance.

Dust stick on light reflectors will affect light transmittance, screen display brightness and color effect.

DLP light reflectors are needed be cleaned regularly.

Provide all series of DLP light reflectors, be applied to Barco, Vtron,  Mitsubishi, Christie, GQY, Toshiba, Delta, YOUNG Optics, LUMENS and other brands.





DLP optical lens


DLP optical lens are used for filtering in optical path.

DLP optical lens fault is rare, only be broken by careless in maintenance.

Dust stick on lens will affect light transmittance, screen display brightness and color effect.

DLP optical lens are needed be cleaned regularly.

Provide all series of DLP optical lens, be applied to Barco, Vtron,  Mitsubishi, Christie, GQY, Toshiba, Delta, YOUNG Optics, LUMENS and other brands.




DMD driver board


DMD driver board failure will lead to no signal display, black screen display, etc.

It is easily caused failure that operation under high temperature or instable voltage.

DLP power failure could be repaired or replaced according to specific situation.

Provide all series of DMD driver board, be applied to Barco, Vtron,  Mitsubishi, Christie, GQY, Toshiba, Delta, YOUNG Optics, LUMENS and other brands.




RGB signal board


RGB signal board failure will lead to no signal, fuzzy, overlap image etc.

It is easily caused failure that operation under high temperature or instable voltage.

RGB signal board failure could be repaired or replaced according to specific situation.

Provide all series of RGB signal board, be applied to Barco, Vtron,  Mitsubishi, Christie, GQY, Toshiba, Delta, YOUNG Optics, LUMENS and other brands.




RGB cables


Aging, broken, or bite by the rat will result in signal transmission fault.

Frequently insert and pull plug make it loosewhich will result in 

signal transmission fault.

Plug would be oxidized after long time use. Recommend replace cables every 3 years.





Output card of image controller


The card failure will lead to no signal, fuzzy, overlap image, black screen display etc. 

It is easily caused failure that operation under high temperature or instable voltage.

The card failure could be repaired or replaced according to specific situation.

Provide all series of output card of image controller, be applied to Barco, Vtron,  Mitsubishi, Christie, GQY, Toshiba, Delta, YOUNG Optics, LUMENS and other brands.





Display card of image controller


The card failure will lead to no signal, fuzzy, overlap image, black screen display etc. 

It is easily caused failure that operation under high temperature or instable voltage.

The card failure could be repaired or replaced according to specific situation.

Provide all series of display card of image controller, be applied to Barco, Vtron,  Mitsubishi, Christie, GQY, Toshiba, Delta, YOUNG Optics, LUMENS and other brands.